| Type | Scope of application | Area of application | Capacity m3/h | PE* | Weight kg | Tank volume | Download |
| AWALIFT 100 | Building services engineering | - Detached and semi-detached houses
- Basement flat
- Party room
| 0,4 | 20 | approx. 78 | 48 l | Product data sheet |
| AWALIFT 74/1 | Building services engineering | - Apartment blocks
- Guesthouses
- Larger plots of land
| 1 | 50 | approx. 110 | 80 l | Product data sheet |
| AWALIFT 0/1 | Building services engineering | - Apartment blocks
- Hotel complexes
- Properties that cannot be drained using natural gradients
- to protect against backflow damage
| 3 | 150 | approx. 190 | 112 l | Product data sheet |
| AWALIFT 74/2 | Building services engineering and municipal applications | - Underground stations
- Airports
- Business parks
- Hospitals
- Hotels and restaurants
- Apartment blocks
| 4 | 200 | approx. 175 | 107 l | Product data sheet |
| AWALIFT 0/2 | Building services engineering and municipal applications | - Underground stations
- Airports
- Business parks
- Hospitals
- Hotels or public buildings
- Apartment blocks
- Properties without drainage via a natural gradient
| 6 | 300 | approx. 320 | 205 l | Product data sheet |
| AWALIFT 1/2 | Municipal applications | - Industrial sites
- Individual streets
- Business parks
- Airports
- Hotels or public buildings
- To protect against backflow damage
- Properties without drainage via a natural gradient
| 15 | 750 | approx. 520 | 430 l | Product data sheet |
| AWALIFT 1/2x2 | Municipal applications | - Small settlements that cannot be drained using natural gradients
- Drainage for higher delivery heads and long pressure pipes
- As an intermediate pumping station within a pressure drainage system
- Residential and industrial areas
- Settlements
- Local authorities
- Infrastructure facilities, such as airports, business parks, underground railways, etc.
| 15 | 750 | approx. 650 | 0,785 m³ | Product data sheet |
| AWALIFT 1/2 penta | Municipal applications | - Larger buildings
- Industrial sites
- Individual streets
- Properties that cannot be drained using natural gradients
- To protect against backflow damage
- Infrastructure facilities, such as airports
- Business parks, underground railways, etc.
| 20 | 950 | approx. 525 | 0,65 m³ | Product data sheet |
| AWALIFT 2/2 penta | Municipal applications | - Drainage of small settlements that cannot be drained by natural gradient
- as an intermediate pumping station within a pressure drainage system
- Residential and industrial areas
- Local authorities
- Infrastructure facilities, such as airports, business parks, underground railways, etc.
| 25 | 1200 | approx. 800 | 1,4 m³ | Product data sheet |
| AWALIFT 2/2 penta | Municipal applications | - Drainage of small settlements that cannot be drained by natural gradient
- as an intermediate pumping station within a pressure drainage system
- Residential and industrial areas
- Local authorities
- Infrastructure facilities, such as airports, business parks, underground railways, etc.
| 36 | 1700 | approx. 800 | 1,4 m³ | Product data sheet |
| AWALIFT 2/2 flach | Municipal applications | - Drainage of small settlements that cannot be drained by natural gradient
- as an intermediate pumping station within a pressure drainage system
- Residential and industrial areas
- Local authorities
- Infrastructure facilities, such as airports, business parks, underground railways, etc.
| 36 | 1700 | approx. 800 | 0,95 m³ | Product data sheet |
| AWALIFT 2/2 rund** | Municipal applications | - Drainage of small settlements that cannot be drained by natural gradient
- as an intermediate pumping station within a pressure drainage system
- Residential and industrial areas
- Local authorities
- Infrastructure facilities, such as airports, business parks, underground railways, etc.
| 60 | 2800 | approx. 800 | 1,40 m³ | Product data sheet |
| AWALIFT 2/2x2 | Municipal applications | - Drainage of small settlements that cannot be drained by natural gradient
- as an intermediate pumping station within a pressure drainage system
- Residential and industrial areas
- Local authorities
- Infrastructure facilities, such as airports, business parks, underground railways, etc.
| 60 | 2800 | approx. 800 | 1,40 m³ | Product data sheet |
| AWALIFT 3/2** | Municipal applications | - Drainage of small settlements that cannot be drained by natural gradient
- as an intermediate pumping station within a pressure drainage system
- Residential and industrial areas
- Local authorities
- Infrastructure facilities, such as airports, business parks, underground railways, etc.
| 80 | 3700 | approx. 1000 | 2,40 m³ | Product data sheet |
| AWALIFT 4/2** | Municipal applications | - Residential and industrial areas
- Drainage of built-up areas
- Local authorities
- Airports, underground railways, etc.
- Properties that can be drained using natural gradients
- as an intermediate pumping station within a pressure drainage system
| 120 | 5600 | approx. 1500 | 4,00 m³ | Product data sheet |
| AWALIFT 5/2** | Municipal applications | - Residential and industrial areas
- Neighbourhoods
- Towns and local authorities
- Drainage of towns that cannot be drained by natural gradient
- As an intermediate pumping station within a pressure drainage system
- Airports, underground railways, etc.
| 150 | 7000 | approx. 1700 | 4,80 m³ | Product data sheet |
| AWALIFT 6/2** | Municipal applications | - small towns
- local authorities
- neighbourhoods
- Infrastructure facilities such as airports, business parks, underground railways, etc.
- Drainage of areas that cannot be drained by natural gradient
- as an intermediate pumping station within a pressure drainage system
| 200 | 9300 | approx.. 2000 | 6,00 m³ | Product data sheet |
| AWALIFT 6/3** | Municipal applications | - Small towns
- Local authorities
- Residential and industrial areas
- Infrastructure facilities, such as airports, business parks, exhibition centres, underground railways, etc.
| 250 | 11600 | approx. 2300 | 6,00 m³ | Product data sheet |
| AWALIFT 7/3** | Municipal applications | - Cities
- Local authorities
- Infrastructure facilities, such as airports and exhibition centres
- Areas that cannot be drained using natural gradients
- as an intermediate pumping station within a pressure drainage system
| 350 | 16200 | approx. 3500 | 9,00 m³ | Product data sheet |
| AWALIFT 8/3** | Municipal applications | - Cities
- Local authorities
- Residential and industrial areas
- Airport grounds
- Drainage of areas that cannot be drained by natural gradients.
| 400 | 18600 | approx. 3800 | 11,00 m³ | Product data sheet |
| AWALIFT 9/4** | Municipal applications | - Drainage of towns and cities that cannot be drained by natural gradient
- as an intermediate pumping station within a pressure drainage system
- Local authorities
- Infrastructure facilities, such as airports, business parks, etc.
| 600 | 28000 | approx. 4500 | 14,00 m³ | Product data sheet |
| AWALIFT 10/6** | Municipal applications | - Drainage of towns and cities that cannot be drained by natural gradient
- as an intermediate pumping station within a pressure drainage system
- Local authorities
- Residential and industrial areas
- Infrastructure facilities, such as airports, business parks, etc.
| 800 | 37000 | approx. 6300 | 26,00 m³ | Product data sheet |