Sewage pumping stations

The strate system.innovative and state-of-the-art wastewater technology.

For more than 75 years, we have been providing innovative solutions for every stage of the wastewater cycle. In doing so, we contribute to the protection and safe transport of wastewater around the world.

Sewage pumping stations

Efficient drainage solutions.The AWALIFT system from STRATE.

With the STRATE AWALIFT sewage pumping stations, we offer technically advanced solutions for safe and cost-effective drainage – both in the municipal sector and in building services. Whether handling large volumes of wastewater in municipal networks or used for domestic and property drainage: our systems are characterised by high operational reliability, low maintenance requirements and exceptional durability – even at high pump heads.

Sewage pumping stations

Building services engineering.Reliable drainage for residential and commercial properties.

STRATE sewage pumping stations for building services are compact, fully automatic systems used wherever sewage cannot flow into the public sewerage system via a natural gradient – for example, in basements, underground car parks or in buildings located below the backflow level. They are designed in accordance with relevant standards such as DIN EN 12056-4 and are suitable for detached and terraced houses, small commercial premises, medical practices or similar buildings.

The systems operate using the patented separator system, which separates coarse solids from the effluent and effectively protects the pumps from blockages. Thanks to their compact design, dry installation and good accessibility, maintenance and operation are straightforward. STRATE pumping systems for building services offer a practical, durable and safe drainage solution for challenging installation conditions.

sewage pumping stations

Municipal applications.High-performance pumping systems for infrastructure and large-scale projects.

For larger infrastructure projects and municipal networks, STRATE offers high-performance sewage pumping stations with a large flow capacity. These systems are used in municipal facilities, business parks, neighbourhoods, small towns and large public buildings where drainage via gravity is not possible or where large volumes of water need to be moved.

STRATE pumping systems for municipal applications are also based on the proven separator system and are designed to meet high operational demands – featuring robust tanks, optimised pumps, gas-tight designs and optional redundant pump technology. Thanks to their modular design and customisation options, they can be tailored to the size of the catchment area and the planned population or wastewater volumes.

sewage pumping stations

Strate AWALIFT sewage pumping stations.A wide range of applications.

STRATE AWALIFT sewage pumping stations are suitable for domestic and property drainage as well as for municipal drainage. We can achieve pump heads of up to 120 metres. This means that a single pumping station can replace several submersible pumping stations. The fully automatic and flood-proof sewage pumping stations, featuring the tried-and-tested separator system, are used for the drainage of larger properties. High operational reliability is achieved through the use and alternating operation of two pumps in larger systems. There is no need for standby pumps. These systems also feature a gas- and odour-tight tank, the surfaces of which are coated with a high-quality anti-corrosion coating.

 

Type

Scope of application

Area of application

Capacity
m3/h
PE*Weight
kg
Tank
volume
Download
 
AWALIFT 100

Building services engineering 

  • Detached and semi-detached houses
  • Basement flat
  • Party room
0,420approx. 7848 l

Product data sheet

AWALIFT 74/1Building services engineering 
  • Apartment blocks
  • Guesthouses
  • Larger plots of land
150approx. 11080 l

Product data sheet

AWALIFT 0/1Building services engineering 
  • Apartment blocks
  • Hotel complexes
  • Properties that cannot be drained using natural gradients
  • to protect against backflow damage
3150approx. 190112 l

Product data sheet

AWALIFT 74/2

Building services engineering and

municipal applications

  • Underground stations
  • Airports
  • Business parks
  • Hospitals
  • Hotels and restaurants
  • Apartment blocks
4200approx. 175107 l

Product data sheet

AWALIFT 0/2

Building services engineering and

municipal applications

  • Underground stations
  • Airports
  • Business parks
  • Hospitals
  • Hotels or public buildings
  • Apartment blocks
  • Properties without drainage via a natural gradient
6300approx. 320205 l

Product data sheet

AWALIFT 1/2Municipal applications
  • Industrial sites
  • Individual streets
  • Business parks
  • Airports
  • Hotels or public buildings
  • To protect against backflow damage
  • Properties without drainage via a natural gradient
15750approx. 520430 l

Product data sheet

AWALIFT 1/2x2Municipal applications
  • Small settlements that cannot be drained using natural gradients
  • Drainage for higher delivery heads and long pressure pipes
  • As an intermediate pumping station within a pressure drainage system
  • Residential and industrial areas
  • Settlements
  • Local authorities
  • Infrastructure facilities, such as airports, business parks, underground railways, etc.
15750approx. 6500,785 m³

Product data sheet

AWALIFT 1/2 pentaMunicipal applications
  • Larger buildings
  • Industrial sites
  • Individual streets
  • Properties that cannot be drained using natural gradients
  • To protect against backflow damage
  • Infrastructure facilities, such as airports
  • Business parks, underground railways, etc.
20950approx. 5250,65 m³

Product data sheet

AWALIFT 2/2 pentaMunicipal applications
  • Drainage of small settlements that cannot be drained by natural gradient
  • as an intermediate pumping station within a pressure drainage system
  • Residential and industrial areas
  • Local authorities
  • Infrastructure facilities, such as airports, business parks, underground railways, etc.
251200approx. 8001,4 m³

Product data sheet

AWALIFT 2/2 pentaMunicipal applications
  • Drainage of small settlements that cannot be drained by natural gradient
  • as an intermediate pumping station within a pressure drainage system
  • Residential and industrial areas
  • Local authorities
  • Infrastructure facilities, such as airports, business parks, underground railways, etc.
361700approx. 8001,4 m³

Product data sheet

AWALIFT 2/2 flachMunicipal applications
  • Drainage of small settlements that cannot be drained by natural gradient
  • as an intermediate pumping station within a pressure drainage system
  • Residential and industrial areas
  • Local authorities
  • Infrastructure facilities, such as airports, business parks, underground railways, etc.
361700approx. 8000,95 m³

Product data sheet

AWALIFT 2/2 rund**Municipal applications
  • Drainage of small settlements that cannot be drained by natural gradient
  • as an intermediate pumping station within a pressure drainage system
  • Residential and industrial areas
  • Local authorities
  • Infrastructure facilities, such as airports, business parks, underground railways, etc.
602800approx. 8001,40 m³

Product data sheet

AWALIFT 2/2x2Municipal applications
  • Drainage of small settlements that cannot be drained by natural gradient
  • as an intermediate pumping station within a pressure drainage system
  • Residential and industrial areas
  • Local authorities
  • Infrastructure facilities, such as airports, business parks, underground railways, etc.
602800approx. 8001,40 m³

Product data sheet

AWALIFT 3/2**Municipal applications
  • Drainage of small settlements that cannot be drained by natural gradient
  • as an intermediate pumping station within a pressure drainage system
  • Residential and industrial areas
  • Local authorities
  • Infrastructure facilities, such as airports, business parks, underground railways, etc.
803700approx. 10002,40 m³

Product data sheet

AWALIFT 4/2**Municipal applications
  • Residential and industrial areas
  • Drainage of built-up areas
  • Local authorities
  • Airports, underground railways, etc.
  • Properties that can be drained using natural gradients
  • as an intermediate pumping station within a pressure drainage system
1205600approx. 15004,00 m³

Product data sheet

AWALIFT 5/2**Municipal applications
  • Residential and industrial areas
  • Neighbourhoods
  • Towns and local authorities
  • Drainage of towns that cannot be drained by natural gradient
  • As an intermediate pumping station within a pressure drainage system
  • Airports, underground railways, etc.
1507000approx. 17004,80 m³

Product data sheet

AWALIFT 6/2**Municipal applications
  • small towns
  • local authorities
  • neighbourhoods
  • Infrastructure facilities such as airports, business parks, underground railways, etc.
  • Drainage of areas that cannot be drained by natural gradient
  • as an intermediate pumping station within a pressure drainage system
2009300approx.. 20006,00 m³

Product data sheet

AWALIFT 6/3**Municipal applications
  • Small towns
  • Local authorities
  • Residential and industrial areas
  • Infrastructure facilities, such as airports, business parks, exhibition centres, underground railways, etc.
25011600approx. 23006,00 m³

Product data sheet

AWALIFT 7/3**Municipal applications
  • Cities
  • Local authorities
  • Infrastructure facilities, such as airports and exhibition centres
  • Areas that cannot be drained using natural gradients
  • as an intermediate pumping station within a pressure drainage system
35016200approx. 35009,00 m³

Product data sheet

AWALIFT 8/3**Municipal applications
  • Cities
  • Local authorities
  • Residential and industrial areas
  • Airport grounds
  • Drainage of areas that cannot be drained by natural gradients.
40018600approx. 380011,00 m³

Product data sheet

AWALIFT 9/4**Municipal applications
  • Drainage of towns and cities that cannot be drained by natural gradient
  • as an intermediate pumping station within a pressure drainage system
  • Local authorities
  • Infrastructure facilities, such as airports, business parks, etc.
60028000approx. 450014,00 m³

Product data sheet

AWALIFT 10/6**Municipal applications
  • Drainage of towns and cities that cannot be drained by natural gradient
  • as an intermediate pumping station within a pressure drainage system
  • Local authorities
  • Residential and industrial areas
  • Infrastructure facilities, such as airports, business parks, etc.
80037000approx. 630026,00 m³

Product data sheet

* PE in dry weather plus extra water (1000 PE ^= 6 l/s)
** Large pumping heads are achieved by switching 2 pumps in series (e.g.: AWALIFT 1/2x2)


Sewage pumping stations

Any questions?Please get in touch with us.

If you would like to find out more about our STRATE sewage pumping stations, please take a look at our product catalogue. Alternatively, you can contact us directly.


Sewage pumping stations

Download.